The HVC1205A0 is a compact, safe, low-leakage, and electrically stable integrated X-ray source. It can operate continuously at 500W within the allowable temperature range. The maximum output voltage can reach 120kV/500W. The integrated X-ray source mainly consists of a control box and high-voltage oil tank. The system uses RS232 interface for control, monitoring, and firmware upgrades.
Food testing, industrial non-destructive, security application and other fields.
Item | Specification |
Input voltage | 230VACยฑ10%, 50/60Hz, 4.2Amps |
Output power of X ray tube | Max continuous output power 500W๏ผ100kV/5mA or 120kV/4.1mA๏ผ |
Output voltage | Rated output voltage๏ผContinuously adjustable voltage range 30kV—120kV |
Output voltage ripple๏ผยฑ0.5%๏ผpeak to peak๏ผ | |
Output voltage accuracy๏ผยฑ2% of voltage setting value | |
line regulation๏ผยฑ0.1% | |
load regulation๏ผยฑ0.1% | |
Tube current | Rated tube current๏ผContinuously adjustable current range 0.2mA-5.0mA |
Tube current accuracy๏ผยฑ0.2mA of current setting value | |
line regulation๏ผยฑ0.1% | |
load regulation๏ผยฑ0.1% | |
Rise time of output voltage | The kV rise time is <0.6 Sec at maximum power |
The kV rise time is <0.1 Sec at low voltage ( < 40kV ) | |
Filament power supply: | input voltage๏ผ24VDC |
filament voltage๏ผ3.7Vac | |
filament๏ผ3.0 to 3.5 Amps RMS | |
preheating time๏ผ3sec | |
Tube feature | Tube type๏ผfixed anodeใglass envelopeใtungsten target |
focus๏ผ0.8mm | |
inherent filtration๏ผ0.8mm Be๏ผ0.7mm AI | |
radiation angle๏ผ80ยฐร36ยฐfan beam | |
target angle๏ผ25ยฐ | |
Cooling | transformer oil๏ผexternal circulation๏ผexternal forced air cooling |
Working temperatures | -10โ—40โ |
Storing temperature | -20โ—60โ |
System temperature protection | 60ยฑ3โ of oil temperature |
Humidness | 98%๏ผNon-condensation |
Weight | Oil tank๏ผ28.5kg |
Control Unit๏ผ3.8kg | |
Installation direction | Installation in any direction |
Radiation angle | 36ยฐร80ยฐ |
X-ray leakage | Less than 0.5mR/hr @5cm from the surface of the HVC1205A0. |
JB1/AC~(AC Input Power Connector)
Pin | Signal | Parameter |
1 | L | live wire |
2 | N | Neutral line |
3 | G | PE |
JB2/COM (DMR-9S interface definitions)
Pin | Signal | Parameter |
1.4.6.7.8.9 | N/C | No connect |
2 | TXD | Data transmit |
3 | RXD | Data receive |
5 | GND | Signal gnd |
JB3/Interlock,(DMR-9P interface definitions)
Pin | Signal | Parameter |
3/4/5/6/7/8/9 | N/C | No connect |
1 | Interlock Out | |
2 | Interlock In |
Short connect pin1 and pin2 make X ray source normal operation. Typical connection๏ผ
Led indicator:
ID | Color | Meaning |
XrayOn | Yellow | indicate X ray on |
ARC | Red | Arcing in oil tank |
OT | Red | Over temperature |
EP_Err | Red | Tube voltage error |
IP_Err | Red | Tube current error |
Power | Green | Power on |
Tank size
Copyright@2024, All Rights Reserved