HVP10012A2 X-Ray Source

Key Features:

  • Compact and convenient design with highly integrated electrical modules
  • Excellent electromagnetic compatibility
  • Compatible with continuous, pulse, and dual-energy operating modes
  • Can be installed in any orientation
  • Standard RS-232 interface for easy application and stable, reliable data exchange

Product Details

The HVP10012A2 is a compact, portable, and reliable high-voltage X-ray generator designed for dental imaging equipment. It can continuously operate at up to 1000W for 25 seconds within the specified temperature range, relying on self-cooling without the need for additional cooling. This X-ray source can output 100kV/1000W in continuous mode (1200W in pulse mode) and features high frequency, self-cooling, self-protection, and independent control. It consists of an X-ray high-voltage oil tank and a control box, with control, status monitoring, and programming managed through a DB9 interface. Additionally, the HVP10012A2 supports both continuous and pulse operation modes.

Application:

Dental X-ray imaging equipment (CT and panoramic), head scan and mobile imaging equipment

Specification:

Item Specification
Input voltage 230VACยฑ10%, 50/60Hz,Single Phase, 6.2Amps, PF>0.98.
Output power of X ray tube Maximum continuous output power 1000W up to 25s (100kV, 10mA)
Maximum pulse output power 1200W up to 40s (100kV, 12mA)
Output voltage The high voltage is programmed with the range of 50 to 100KV
Output voltage ripple๏ผšยฑ0.5%๏ผˆpeak to peak๏ผ‰
Output voltage accuracy๏ผšยฑ1% of voltage setting value
line regulation๏ผšยฑ0.1%
load regulation๏ผšยฑ0.1%
Tube current 2mA to 10mA at 1000W MAX, continuous
2mA to 12mA at 1200W MAX, pulse
Tube current accuracy๏ผšยฑ0.1mA of current setting value
mA Regulation:<ยฑ0.1mA for Line Input changes of ยฑ10%;
<ยฑ0.1mA for the output voltage change over the specified range
Filament power supply: input voltage๏ผš24VDC
filament voltage๏ผš2.5 to 6.8VAC
filament๏ผš3.2 to 3.8A
preheating time๏ผš3sec
Tube feature Tube type๏ผšfixed anodeใ€glass envelopeใ€tungsten target
focus๏ผš0.5mm
inherent filtration๏ผš 1.8mm AI
radiation angle๏ผšย  20ยบ, cone beam
target angle๏ผš 5ยฐ
Operation mode Continuous mode, pulse mode
Pulse frequency 20-50Hz
Pulse time Single pulse exposure time๏ผš5.0๏ฝž50ms
Dual energy setting Arbitrary setting of two different energy voltage levels of tube voltage within the rated range
Max exposure time Maximum continuous exposure time 25s at continuous mode
Maximum continuous exposure time 40s at pulse mode
Kv Rise Time at maximum power: Continuous mode: To 100kV and 10mA in less than 15ms
Pulse mode: rise time of single pulse kV less than 1ms
Cooling transformer oil๏ผŒaluminum shell natural heat dissipation
Working temperatures -10โ„ƒ—40โ„ƒ
Storing temperature -20โ„ƒ—60โ„ƒ
System temperature protection 60ยฑ3โ„ƒ of oil temperature
Humidness 10%-95%๏ผŒNon-condensation
Weight Oil tank๏ผš8.4kg
Control Unit๏ผš3.6kg
Installation direction Installation in any direction
Radiation angle cone angle of ray tapered beam 20ยฐ
X-ray leakage Less than 100mR/hr at 1meter from the surface of the HVP10012A2 Integrated X-Ray Source.

JB1/AC~(AC Input Power Connector)

Pin Signal Parameter
1 L live wire
2 N Neutral line
3 G PE

JB2/COM(Communication Interface, DMR-9S(female)

Pin Signal Parameter
1.4.6.7.8.9 N/C Undefined
2 TXD Data transmit
3 RXD Data receive
5 GND Reference ground

JB3 (Signal Interface, DMR-9P(male)

Pin Signal Parameter
1 Interlock Out
2 Interlock In
3 Syn_ Out synchronizingย signal output
4 Syn_ In synchronizingย signal input
5 GND Reference gnd
6 Syn_Out synchronizingย signal output
7 GND Reference ground
8 N/C Undefined
9 Xray_ON X-ray switch signal pin.